Hawkesworth provides emergency lighting testing for offices, warehouses, public-sector and multi-site premises across the UK and Ireland, delivered by qualified and competent engineers. As an experienced emergency lighting testing company, we confirm that your emergency luminaires operate when normal lighting fails, carrying out the monthly functional test and annual full-duration test, and record every fault clearly to support your fire safety duties.
Before attendance, we confirm luminaire numbers and types, system design, building use, access, test facilities and suitable testing times. A qualified and competent engineer visually inspects accessible emergency luminaires and signs, checking condition, security and cleanliness and noting obvious damage. The agreed inspection also covers units serving areas such as exits, escape routes, stairways and changes of level.
For the monthly functional test, normal lighting failure is simulated for long enough to confirm that each emergency luminaire switches to its emergency supply. For the annual full-duration test, the luminaires operate from their emergency supply for their full rated duration, commonly one or three hours depending on system design. Start and finish times are recorded, and any unit that fails to illuminate or remain lit is identified.
After testing, the normal supply is restored and indicators are checked to confirm charging has resumed. Hawkesworth provides electronic service records and certification, with asset details, locations, failures and observations recorded clearly. Urgent concerns are reported to the site contact, and remedial work can be quoted separately.
Three steps to a compliant site
Plan the visit
Confirm the system scope, luminaire details, access, test duration and suitable testing times.
Inspect and test
Complete visual checks, the monthly functional test or the agreed annual full-duration test.
Restore and report
Reinstate the normal supply, check charging indicators and issue electronic records with clear findings.
Why Hawkesworth?
More than a tick-box visit
Support across your sites
Whether you manage one premises or a national estate, our nationwide coverage helps you coordinate Emergency Lighting Testing across the UK and Ireland.
Testing planned around you
Out-of-hours and weekend testing is available to help minimise disruption and give emergency lighting batteries time to recharge.
Clear records after every visit
Electronic service records and certification are provided for completed work, helping you keep your compliance documentation organised and up to date.
Support with follow-up actions
If defects are identified, we can provide clear remedial quotations, help coordinate the next steps and send renewal reminders to keep future testing on track.
Rated 4.9 by 200+ reviews
I've used Hawkesworth PAT testing services historically and always found them to be super quick and very efficient at the job. This hasn't changed, having had to request their support on some recent work and did a brilliant job as always. The certs were sent across super quick as well ensuring our compliance records were up to date.
Hawkesworth arranged my date and time efficiently and on the day the representative was both thorough and efficient. Thanks very much indeed!.
Very professional and efficient service. The organisation process was very easy and they contacted us the week of testing to ensure all was well and to confirm a start time. When Hawesworth were on site we barely knew that they were here and caused very little disruption. Would definitely recommend their service.
Great service from Hawkesworth. The local engineer, was prompt, efficient, pleasant and respectful of our continuing operations whilst on site.
FAQs
Questions, answered
How often should emergency lighting be tested?
Emergency lighting should normally receive a brief functional test every month and a full-rated-duration test every year, unless the system design, fire risk assessment or local requirements call for a different arrangement.
What is the difference between a functional test and a full-duration test?
A functional test confirms that emergency luminaires switch on when normal lighting failure is simulated. A full-duration test checks that they remain illuminated for their full rated period.
Will Emergency Lighting Testing affect normal site operation?
A functional test is brief, but a full-duration test leaves batteries needing time to recharge. Testing should therefore be planned for a period of low risk and around site operations.
What happens if a luminaire or battery fails?
The failed unit, location and observation are recorded and communicated to the site contact. Hawkesworth can provide a clear quotation for agreed remedial work.